M60 Alarm Dialer Event Viewer Upgrade
The Event Viewer allows for a visual display of the last 4 Events that have occurred on the M60 Alarm Dialler.
Events are either a dial-out due to an active alarm, or a call-back to cancel the M60 from continuing to dial-out.
Each Event will use a single line on the display.
Dial-out Event
A Dial-out Event will occur whenever the M60 has completed the dialling of a telephone number.
The Dial-out Event will always show the time followed by the Date and Month and then the first two active alarms separated by a comma. The last character on the line informs the user if there were no other active alarms or there are more active alarms than displayed.
Call-back/Cancellation Event<.......
-
Key switch Options
On a standard M30 the Key switch located on the front will simply turn the M30 ON or OFF, ideal if you are doing work on site, the site is temporary closed or maybe you simply just want it active when the office is closed.
But the Key switch can be set up to work in other ways;
- Always answer any call when switched on.
- Only accept Interrogation calls.
- You cannot Cancel the M30 via callback only '0' key, but you can still remotely interrogate it.
- Only accept Call-back calls
- You cannot interrogate the M30, but you can still remotely cancel the M30 via callback.
.......
-
Generator Alarm System
The M30 Generator Alarm System provides an easy and reliable method to monitor your Generators and Power Plants especially in remote or unmanned locations where it is critical to have a constant power connection.
When a problem occurs the M30 will instantly alert the current on call personal by voice and or SMS message to tell them there is a problem on site.
Not only can you monitor mains failure detection and generator stop / starts you can also monitor other aspects of the generator e.g. fuel levels, over heating alerts. Plus you can connect anything else on the site than you would like to monitor e.g. Security systems, High/Low temperatures, Water levels etc.
GSM and SMS .......
-
Lone Worker SystemProviding a foolproof method for protecting your staff with out the need for remote fobs or radio equipment. Not only does this save you the worry of of whether the fobs are working and are charged it also means it can be used in places where Radio use is prohibited.
For more information visit our Lone Worker page or contact us.
-
Auto Dialer with Text Message Facility
The M30 Auto dialer With Text Message Facility is an advanced purpose built unit designed for critical and harsh environments.
As an industrial Auto Dialer the M30 comes with all the types of feature you would expect, 4-56 individual inputs, PSTN, GSM, SMS, Pager communications, Fully LCD display & Keypad driven, hardened electronics and multiple backup systems.
Its backup systems include 24-48 hour battery backup, phone line monitoring, GSM phone line Backup, text messages and multiple dialout numbers.
Text Message Facility
The M30 allows you to have a fully customisable text message for each alarm input, meaning you won't receive a cryptic "Channel 16 ala.......
-
SMS Alarm Auto DialerThe M30 SMS Auto Dialer is an industrial unit, purposely designed for harsh commercial situations.
As a commercial piece of equipment it comes with all the features you would expect; 4 to 56 individual inputs, integrated battery backup, high spec components , inbuilt surge protection and is fully configurable via its inbuilt LCD and keypad system.The M30 is used around the world in a multitude of situations from Horticulture in Wales, Hotels & Hospitals in London, Power stations in Scotland, Building management systems in Qatar, desalination plants in Florida and railways in Hong Kong.
SMS Text message feature
Each input on the M30 has its own individual SMS text mes.......
-
New V50 software released for the M30 Alarm Dialer
The new V50 software version has many new features and improvements, but the main changes are listed below. Keypad
The M30 will now automatically progress to the next slot after a phone number has been added or edited.
The only exception is if it is already at the last slot in that roster/group.
Delays
All Dial out delays on the M30 can now be skipped over/though by simply pressing the "ESC" key.
This includes the Input delay, Inter-dial out delay and the Extended pause delay.
Number Skip Dial out Feature
The M30 now gives you the ability to manually select the number to be dialed from the currently selected roster.
For example during your .......
-
SMS Alarm Dialer
The M30 SMS Alarm Dialer is an rugged machine specifically designed for commercial and industrial conditions. It has over 60 years of alarm dialer design experience behind it and was designed with input from our customers to make sure it had all the features and functions they required.The M30 SMS features include 4,8,16 or 56 individual inputs each with their own SMS or voice message, IP56 enclosure, integrated mains failure and 24+hrs battery backup to name a few (check out a more in-depth list below).
SMS features;
The SMS feature is very easy to setup, when you are setting up the outgoing alarm contact numbers you just select whether you would like the recipient to get an SMS .......
-
CTR Channel to Roster Software Upgrade
On a Standard M30 on when dialing it will select the Duty Roster set by the User (1,2 or 3). The current Duty Roster selected is shown on the top right of the LCD display (e.g. R1, R2, R3).
The Channel to Roster software works differently. When an alarm becomes active, instead of the M30 dialling out on one of the Duty Rosters, the M30 will automatically select a Roster linked to that alarm channel.
So for Example;
If Channel 1 is activated it will dial Roster 1.
If Channel 5 is activated it will dial Roster 5.
If Channel 10 is activated it will dial Roster 10 etc.
This software upgrade is great for when you need to communicate different alarms to different people for example t.......
-
SMS Auto Dialer
The M30 SMS Auto Dialer was purposely designed for use in harsh industrial environments and was designed with both our 50 plus years of experience and our customers input making it our most robust and feature rich unit to date. The M30 comes with a multitude of features including an IP56 enclosure, integrated battery backup and 4,8,16 or 56 separate inputs (check out more below).
SMS
Each input has its own individually definable SMS / Text Message, so instead of a “Channel 1 Alarm” you could receive a much more useful “Westbury Landfill – Mains Failure in building 2”.
When an alarm is activated the M30 will send an SMS for each active alarm to the preprogrammed recipien.......