Cookies and your Privacy
01344 874114
4,8,16,56 Alarm Inputs,GSM or Land Line Networks,No Need for a Fixed Line,Real Speech Messages,24hrs Battery Backup,Remote Interrogation,Fully Menu Driven,Call Back to Cancel, Analogue Inputs , Insurance Approved
Click Here to Contact us today to get the latest information and pricing

Tagged: autodialer Toggle Comment Threads | Keyboard Shortcuts

  • M60 Alarm Dialer 3:21 pm on May 9, 2013 Permalink |
    Tags: , , , , autodialer, ,   

    Alarm Dialers; Guide to our Alarm Dialers 

    Guide to our Rugged Alarm Dialers

    All of our Alarm Dialers below come with as standard;

    • Multiple Dialout Lists.
    • Digital Switched inputs suitable for –
      • Temperature
      • Power
      • Humidity
      • Vac
      • Anything that provides a NO or NC volt free contact.
        • If you can only supply a voltage, we can supply a relay interface module.
    • Analog Inputs Available as Optional extra.
    • IP56 Industrial Enclosure.
    • Integrated Battery Backup.
    • Surge Protection.
    • Alarm Relay Output.
    • Low Battery Alarm
    • Local Audible Alarm.
    • LCD Display.
    • Keypad.
    • Isolated Inputs.
    • Total Isolation Switch.

     

    4 Input Alarm Dialer

    4 Input Alarm Dialer

     

     

    • 4 Channel / Input Industrial Standard M30 Alarm Dialer
      • PSTN only.
    • 4 Channel / Input Industrial Standard M30 Alarm Dialer
      • PSTN & GSM Voice.
    • 4 Channel / Input Industrial Standard M30 Alarm Dialer
      • PSTN & SMS.
    • 4 Channel / Input Industrial Standard M30 Alarm Dialer
      • PSTN, SMS & GSM Voice.

     

    Contact us to get the Current Price list and available Options

     

    8 Input Alarm Dialer

    8 Input Alarm Dialer

     

     

    • 8 Channel / Input Industrial Standard M30 Alarm Dialer
      • PSTN only.
    • 8 Channel / Input Industrial Standard M30 Alarm Dialer
      • PSTN & GSM Voice.
    • 8 Channel / Input Industrial Standard M30 Alarm Dialer
      • PSTN & SMS.
    • 8 Channel / Input Industrial Standard M30 Alarm Dialer
      • PSTN, SMS & GSM Voice.

     

    Contact us to get the Current Price list and available Options

     

    16 Input Alarm Dialer

    16 Input Alarm Dialer

     

     

    • 16 Channel / Input Industrial Standard M30 Alarm Dialer
      • PSTN only.
    • 16 Channel / Input Industrial Standard M30 Alarm Dialer
      • PSTN & GSM Voice.
    • 16 Channel / Input Industrial Standard M30 Alarm Dialer
      • PSTN & SMS.
    • 16 Channel / Input Industrial Standard M30 Alarm Dialer
      • PSTN, SMS & GSM Voice.

     

    Contact us to get the Current Price list and available Options

     

    56 Input Alarm Dialer

    56 Input Alarm Dialer

     

     

    • 56 Channel / Input Industrial Standard M30 Alarm Dialer
      • PSTN only.
    • 56 Channel / Input Industrial Standard M30 Alarm Dialer
      • PSTN & GSM Voice.
    • 56 Channel / Input Industrial Standard M30 Alarm Dialer
      • PSTN & SMS.
    • 56 Channel / Input Industrial Standard M30 Alarm Dialer
      • PSTN, SMS & GSM Voice.

     

    Contact us to get the Current Price list and available Options

     

     

    If you would like any more information or a current price list please contact us today.

     

     

     
  • M60 Alarm Dialer 2:41 pm on April 2, 2013 Permalink |
    Tags: , , , autodialer, , , , , , ,   

    GSM Alarm Dialler 

    GSM Alarm Dialler with Voice and SMS

    GSMThe M30 GSM Alarm Dialler is an industrial / commercial unit designed for operating in harsh environments. The M30 comes with all the features you would expect from an industrial unit including; 4 to 56 independent inputs each with their own user recordable speech or SMS message and integrated 24+ hour battery backup  to name a few –  see the standard features page for a full list.

    Speech & SMS

    The M30 Dialler now supports both Speech and SMS alarm messages. This can be individually configured for each Dialout. E.g. Dialout 1 to send a speech message to a land line, Dialout 2 to send a speech message to a mobile and Dialout 3 to send an SMS to a mobile.

    GSM & PSTN

    Unlike all other GSM Alarm diallers the M30 also has a PSTN connection, meaning if you wish, you can setup your unit to use the GSM network as a backup connection. I.e. The M30 will monitor your PSTN land line; if it fails or is cut it will automatically switch to the GSM network.

     

    Below is a small subsection of the features that are available on the M30;

    • 4,8,16 & 56 Individual Alarm Inputs.GSM Alarm Dialler
    • Individual Speech Messages for each input.
    • Individual SMS Messages for each input.
    • PSTN & GSM Options.
    • Internal Mains Failure Alarm Sensor.
    • 24+ Hour Internal Battery Backup.
    • Fully Menu and Keypad Driven.
    • IP56 Industrial Rated Enclosure.

    If you would like more information or help on the features of the M30 please visit the standard or optional features pages or contact us directly.

    The M30 is designed and built by us in the UK so if there are any special features you require for your application, we will normally be happy to create them for you.

     If you have any questions or would like pricing please contact us.

     

     

     

     
  • M60 Alarm Dialer 10:54 am on March 25, 2013 Permalink |
    Tags: , , , autodialer, , , , , ,   

    Unmanned Site Alarm System 

    Unmanned Site Alarm System

    Having an unmanned site raises all sorts of questions about how you protect the sites security, the monitoring of any running equipment or processes to the welfare and safety of people or livestock.

    Most of those questions can be fixed by installing various types of monitoring and or alarm systems.Remote Site

    Of course you can have the most advanced alarm system on the planet, monitoring every aspect of your unmanned site, with the loudest bells and strobes. But like the proverbial tree in the forest if there is no one around to hear and respond to the alarm you might as well just have an empty box on the wall.

    This is where the M30 Unmanned Site Alarm Dialler comes in – The M30 connects to your current alarm system or you can wire in all your sensors and monitoring equipment direct to the M30. When the M30 receives an alarm signal it will automatically communicate this to the preprogrammed emergency contact list to inform the current on call personal that there is a problem on site.

    The M30 can connect either to a local PSTN landline or to the GSM mobile phone networks; depending on what you have setup the M30 can send user recordable real speech alarm messages, SMS text messages or data to pagers.

    If you worried about your landline failing or being deliberately tampered with, the M30 can monitor the connected PSTN land line, if this fails or is cut the M30 will automatically switch across to the GSM networks.

    The M30 can also trigger an onsite alarm siren or strobe if you wish.

    Below are some of the features available on the M30;Unmanned Site Alarm

    • 4,8,16 and 56 individual inputs/ channels.
    • Individual user recordable speech and or SMS messages for each input.
    • Voice, SMS, Pager alarm messages
    • PSTN and or GSM phone network connection.
    • Remote 247 Interrogation.
    • Integrated Mains Failure detection.
    • 24 Hour battery Backup
    • Fully Menu and Keypad driven
    • IP56 Industrial enclosure.

    Because the M30 is designed and built by ourselves in the UK if there is a special function you need for your application then we will normally be happy to create it for you.

    The above list is only a small selection of the M30 features, for more comprehensive information please contact us or visit the standard or optional features pages.

     

     
  • M60 Alarm Dialer 11:32 am on August 13, 2012 Permalink |
    Tags: , autodialer, , , , , , ,   

    What is a GSM Alarm Dialler? 

    What is a GSM Alarm Dialler?

    GSM Alarm Diallers are fairly new to the market (i.e. the last 8 years or so) but in that time have shown themselves to be very useful and convenient either as an alternative to a standard Alarm Dialler or as a backup device.

    In situations where it is not practically or financially viable to get a land line installed or where there is a high chance someone might try to block the line a GSM Dialler can be ideal.

    A GSM Alarm Dialler is essentially the same as Landline Version but accepts a sim card and uses the GSM networks to make and receive alarm calls rather than PSTN land lines.

    Not all GSM Diallers are equal most are very cheap and are not designed to cope with commercial or industrial use, nor will they have the features a business might require i.e. multiple dial out lists for different staff rotas. For example the Commercial M30 Autodialler by Packs Infotel can use both Landlines and the GSM network, i.e. The M30 can use the GSM networks all the time or the M30 can use the Land Line networks and only switch to the GSM / Mobile networks if the land line fails.

     

    But you do need to be bare in mind that GSM / Mobile networks are typically less reliable than a fixed land line, as they are more susceptible to weather and local conditions and have a smaller network capacity. E.g. during peak times the mobile networks often become clogged and fall over. Governments also have the power to turn off or disrupt the GSM and or Mobile networks in an emergency.

    Because of this if you application is critical we would recommend where ever possible to use a land line as the primary medium and use the GSM networks as a backup.

     

    For more information visit the M30 GSM Autodialler Page,  GSM Module Page or Contact Us

     

(c) Copyright 2000 - 2026 Industrial GSM Alarm Dialer

Click Here to Contact us today

Return to the M60 Home Page

 

1 Broomfield hall buildings, London road, Sunningdale, Ascot, Berkshire, SL5 0DP, United Kingdom.
 Tel +44 (0)1344 874114 Fax +44 (0)1344 874664

[M60 Autodialer] [Standard Features] [Optional Features] [What is a Alarm Autodialer] [M60 Expander] [GSM Dialler Module]
[
SMS Alarm Messages] [Analogues & Data Logging] [Line Sensing] [Central Station] [M60 Alarm Splitter] [M60 Online Blog]
[
Autodialler Comparison] [Autodialler Applications] [Poultry Alarm System] [Power Station Autodialer] [Building Management Autodialler]
 [
Autodialler Gas & Oil] [Refrigeration & Storage Autodialer] [Land fill Autodialler] [Waste Water Autodialler]
[
Flood Warning Autodialler] [Livestock Autodialler] [Horticulture Autodialler] [SCADA Autodialer] 
[
M60 Data sheets] [M60 Photo Gallery] [Contact Us] [Sitemap] [Cookies]

A Packs Infotel Designed Product

Guildford Website Design

c
Compose new post
j
Next post/Next comment
k
Previous post/Previous comment
r
Reply
e
Edit
o
Show/Hide comments
t
Go to top
l
Go to login
h
Show/Hide help
shift + esc
Cancel